Active power load device product image-resistive load bank-Antai Transformer

Electrical Test Equipment · Test Load Impedance Device

Active Power Load Device

AT series active power load device consists of multiple pure resistor elements, switching control units, cooling system and protection devices. It provides adjustable resistive load with power factor close to 1.0 for AC/DC power supply, generator, transformer, UPS and inverter testing. Widely used for generator factory tests, transformer load loss measurement, UPS aging tests and data center diesel generator load bank exercises.

Application

AT series active power load device is a pure resistive load that converts electrical energy into heat, simulating actual active power consumption of electrical equipment. Main applications include:

Diesel/gas generator factory tests and periodic maintenance load bank tests

Transformer load loss measurement and temperature rise tests

UPS/EPS performance and aging tests

Variable frequency power supply, inverter and shore power supply load tests

Data center diesel generator load bank exercises

MV/LV distribution system active load simulation

EV charger and energy storage PCS active power tests

Marine, railway and mining mobile power station load tests

Structural Features

Pure resistive load: Power factor close to 1.0, truly simulates active power consumption

Multi-stage power adjustment: Multiple independent resistor units, individually switchable for step-by-step power adjustment

AC/DC options: AC type for 50/60Hz systems, DC type for DC power supply tests

High-quality resistor elements: Nickel-chrome alloy or stainless steel resistor strips, high temperature resistant, oxidation resistant, stable resistance

Efficient heat dissipation: Forced air cooling for high power, water cooling or container cooling for ultra-high power

Protective enclosure: Outdoor type with rainproof, dustproof and corrosion-resistant enclosure, IP54-IP65

Intelligent monitoring: Optional electrical parameter meters, temperature monitoring, remote communication (Modbus / IEC 61850)

Safety protection: Over-temperature, over-current, fan failure, phase loss protection and emergency stop

Selection Guide

Generator factory test: Match tested unit rated power, commonly 110% overload for 1 hour

Data center diesel generator exercise: Choose continuous duty, outdoor protection, remote-controlled load bank

Transformer load loss measurement: Choose low-inductance resistive load with power factor close to 1.0

UPS/EPS aging test: Choose step-load device to test output characteristics at different load rates

Shore power supply test: Choose AC type matching ship shore power voltage

Ultra-high power application: Choose containerized water-cooled load for transport and outdoor installation

Frequent switching: Choose contactor or thyristor switching to improve service life